AcceleRAID 170Installation GuideDB11-000022-00 First Edition08P5511
About This ManualThis installation guide covers hardware set-up and configuration procedures necessary for the installation of a Mylex AcceleRAID 170
ConventionsThroughout the manual, the following conventions are used to describe user interaction with the product:prompt This style of type indicates
Manual No. DB11-000022-00 iiiContentsChapter 1IntroductionProduct Description ...
iv AcceleRAID 170 Installation GuideOperating System ...3-5Operating System
Manual No. DB11-000022-00 1-1Chapter 1IntroductionThis chapter describes:• The AcceleRAID™ 170 controller• Standard package contents• User supplied
Product Description1-2 AcceleRAID 170 Installation GuideController FeaturesFeatures of the AcceleRAID 170 controller include:• One QLogic ISP 10160A c
IntroductionManual No. DB11-000022-00 1-3Operating System SupportMS-DOS 5.x, 6.x, and above are supported using drivers that reside in the AcceleRAID
Standard Package Contents1-4 AcceleRAID 170 Installation GuideStandard Package ContentsThe following items are supplied with the standard shipping pac
IntroductionManual No. DB11-000022-00 1-5User-supplied Items The following user-supplied items are required to perform this installation:• IBM-PC™ com
Electromagnetic Compatibility NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This
User-supplied Items1-6 AcceleRAID 170 Installation Guide
Manual No. DB11-000022-00 2-1Chapter 2InstallationThis chapter describes:• Before You Begin• Safety Considerations• Installation Checklist• Connectors
Before You Begin2-2 AcceleRAID 170 Installation GuideBefore You BeginInstalling the AcceleRAID 170 single channel RAID controller is no more difficult
InstallationManual No. DB11-000022-00 2-3Safety ConsiderationsBe sure to observe the following precautions before beginning the controller installatio
Installation Checklist2-4 AcceleRAID 170 Installation GuideInstallation ChecklistGET READY☛ NoteIt is recommended that you wear a grounded wrist strap
InstallationManual No. DB11-000022-00 2-5Connectors, LEDs, and JumpersThere is one external and one internal Ultra 160 SCSI connector supported on the
Connectors, LEDs, and Jumpers2-6 AcceleRAID 170 Installation Guide Figure 2-1. AcceleRAID 170 Controller Channel ConnectorsFigure 2-2. AcceleRAID 17
InstallationManual No. DB11-000022-00 2-7Figure 2-3. AcceleRAID 170 Jumper LocationsTable 2-2. AcceleRAID 170 Jumper DescriptionsJ1 Manufacturing test
Installation Process2-8 AcceleRAID 170 Installation GuideInstallation ProcessInstalling the ControllerFollow these installation steps:1. Choose any av
InstallationManual No. DB11-000022-00 2-9 CautionBe sure to wear a ground wrist strap at all times.3. Handling the AcceleRAID 170 controller by the e
Interference-Causing Equipment Regulations.Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur
Installation Process2-10 AcceleRAID 170 Installation GuidePreparing the SCSI DrivesTo prepare the drives for installation, follow these steps:1. Remov
InstallationManual No. DB11-000022-00 2-11☛ NoteIn order to ensure an error free environment, the proper cable type designed for a certain SCSI speed
Installation Process2-12 AcceleRAID 170 Installation Guide1. Termination - Only Internal or Only External Devices Check that the drive channel is prop
InstallationManual No. DB11-000022-00 2-132. Termination - Both Internal and External Devices Check that the drive channel is properly terminated acco
Installation Process2-14 AcceleRAID 170 Installation GuideSetting SCSI Device IDs4. Set the SCSI ID on the disk drives; ID 7 is reserved for the contr
InstallationManual No. DB11-000022-00 2-15SCSI CablingThe controller supports one Ultra 160 SCSI channel which can support up to 15 SCSI devices (plus
Limitations on Mixing SCSI Drives2-16 AcceleRAID 170 Installation GuideLimitations on Mixing SCSI DrivesNarrow with Wide SCSI DrivesIf you mix narrow
Manual No. DB11-000022-00 3-1Chapter 3Controller Start-upThis chapter describes:•BIOS Options • BIOS Configuration Utility (RAID EzAssist)• Operating
BIOS Options3-2 AcceleRAID 170 Installation Guideoption.
Controller Start-upManual No. DB11-000022-00 3-3Setting BIOS OptionsThe available BIOS options are:• BIOS disabled / enabled• CD-ROM boot disabled / e
Declaration of ConformityPer FCC Part 2, Section 2.1077(a)Manufacturer’s Name: LSI Logic Corporation Manufacturer’s Address:North American Headquarter
BIOS Options3-4 AcceleRAID 170 Installation GuideEnable 8 GByte or 2 GByte Drives This setting affects how the BIOS reads the disk drives for the boot
Controller Start-upManual No. DB11-000022-00 3-5☛ NoteIn the event that the RAID controller needs to be replaced, the current drive geometry will be r
Global Array Manager (GAM) Client3-6 AcceleRAID 170 Installation GuideGlobal Array Manager (GAM) ClientThe controller can be configured using GAM. GAM
Manual No. DB11-000022-00 A-1Appendix AAcceleRAID 170SpecificationsGeneral Hardware SpecificationsAcceleRAID 170Controller AcceleRAID 170CPU i960RM mi
General Hardware SpecificationsA-2 AcceleRAID 170 Installation GuideEnvironmental Specifications Controller AcceleRAID 170Temperature Operating 0°C
Manual No. DB11-000022-00 B-1Appendix BAcceleRAID 170Error Messages☛ NoteThe firmware you are using may have these messages turned off. However, they
Installation AbortB-2 AcceleRAID 170 Installation GuideDuring the initialization, if the firmware fails to respond to the BIOS inquiry within two minu
AcceleRAID 170 Error MessagesManual No. DB11-000022-00 B-3to the RAID EzAssist Configuration Utility User Reference Guide or RAID EzAssist Configurati
System Reboot or Power DownB-4 AcceleRAID 170 Installation Guide
Manual No. DB11-000022-00 C-1Appendix CPCI Hot PlugIntroductionPCI Hot Plug is a feature that allows a PCI card to be replaced while the host system i
Declaration of ConformityPer 89\336\EECResponsible PartyName:LSI Logic Corporation Address:North American HeadquartersMilpitas, CAU.S.A.hereby declare
ImplementationC-2 AcceleRAID 170 Installation Guide• odineb.nlm - This is a module combining the Open Data-link interface and the Novell Event Bus (NE
PCI Hot PlugManual No. DB11-000022-00 C-3Windows NTWindows NT requires additional software from the vendor who makes the system. Since this software i
ImplementationC-4 AcceleRAID 170 Installation Guidethe PCI Hot Plug capability. No additional software is required.Please refer to the Windows XP or .
Manual No. DB11-000022-00 D-1Appendix DEnclosure ManagementIntroductionMylex’s AcceleRAID controllers support the industry standard enclosure manageme
SESD-2 AcceleRAID 170 Installation GuideSESThe AcceleRAID 170 supports SES (SCSI Enclosure System) cabinets. Please refer to the documentation supplie
Manual No. DB11-000022-00 G-1GlossaryAcceleRAID™The AcceleRAID family features high performance, cost effective Ultra SCSI/Ultra2 SCSI LVD and Ultra 1
G-2 AcceleRAID 170 Installation GuideAutomatic RebuildMylex controllers provide automatic rebuild capabilities in the event of a physical disk drive f
GlossaryManual No. DB11-000022-00 G-3BusA set of conductors that connect the functional units in a computer and are the channels through which data is
G-4 AcceleRAID 170 Installation GuideChannelAny path used for the transfer of data and control of information between storage devices and a storage co
GlossaryManual No. DB11-000022-00 G-5DiskA non-volatile, randomly addressable, re-writable data storage device, including rotating magnetic and optica
Community of EuropeCE mark is rated for the AceleRAID 170 as follows: CISPR 22 Radiated EmissionEN55022, Generic immunity standard for the following:I
G-6 AcceleRAID 170 Installation Guideactive controllers (also called Active/Active controllers) are connected to the same set of devices and provide a
GlossaryManual No. DB11-000022-00 G-7eXtremeRAID 1100, 2000, and 3000 provide the highest performance and most flexible RAID solution available today.
G-8 AcceleRAID 170 Installation GuideGigabyte230 (1,073,741,824) bytes. Abbreviated as G or GB.Global Array Manager (GAM)A Mylex RAID management utili
GlossaryManual No. DB11-000022-00 G-9controller to “rebuild” the data on the new drive, all without interrupting system operations. Once the rebuild i
G-10 AcceleRAID 170 Installation GuideI/OInput/Output, the transmission of information between an external source and the computer.I/O BusAny path use
GlossaryManual No. DB11-000022-00 G-11Logical Drive StatesA logical (system) drive can be Online, Critical, or Offline. Notice that the term “online”
G-12 AcceleRAID 170 Installation GuideMirroringRefers to the complete duplication of data on one disk drive to another disk drive, this duplication oc
GlossaryManual No. DB11-000022-00 G-13OfflineA Logical Drive is in an “offline” state if no data can be read from it or written to it. Offline does no
G-14 AcceleRAID 170 Installation GuidePhysical DeviceAny device connected to some kind of hardware. For example, SCSI disk, fibre disk, network disk,
GlossaryManual No. DB11-000022-00 G-15RAID LevelsMylex disk array controllers support four RAID Advisory Board approved (RAID 0, RAID 1, RAID 3, and R
Underwriters Laboratories Statement and Warning
G-16 AcceleRAID 170 Installation GuideRAID MigrationA feature in RAID subsystems that allows for changing a RAID level to another level without poweri
GlossaryManual No. DB11-000022-00 G-17enclosure itself is treated as simply another device on the SCSI bus. Many other leading server, storage, and RA
G-18 AcceleRAID 170 Installation GuideOffline: A SCSI disk drive is in a “offline” state if it is not present, if it is present but not powered on, or
GlossaryManual No. DB11-000022-00 G-19reported, conservative cache is enabled and all system drives are switched to write-through cache. Primarily use
G-20 AcceleRAID 170 Installation GuideTo use the standby rebuild feature, you should always maintain a standby SCSI disk in your system. When a disk f
GlossaryManual No. DB11-000022-00 G-21drive 1, block 2 on SCSI drive 2, block 3 on SCSI drive 3, block 4 on SCSI drive 1, block 5 on SCSI drive 2, and
G-22 AcceleRAID 170 Installation GuideUltra SCSI (Fast 20 SCSI)A high performance SCSI protocol that has a bus speed of 20 Megabytes per second in the
Manual No. DB11-000022-00 Index-1IndexAAborted Installation B-2AcceleRAID 170 1-1capabilities 1-2channels 1-2features 1-2operating system support 1-4s
Index-2 AcceleRAID 170 Installation Guideoperating system support 1-3PPCI Hot Plug C-1Implementation C-1Introduction C-1NetWare C-1Windows 2000 C-3Win
LSI LOGIC CORPORATIONSOFTWARE LICENSE AND WARRANTY POLICYLimited WarrantyLSI warrants to the original purchaser of the product enclosed herein(“Custom
Proprietary Rights NoticeThis document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used b
with LSI’s instructions and the terms of this Agreement, shippingcosts to be borne by LSI, and (c) Customer has provided proof ofpurchase price and da
is a part of the Product (“LSI Software”) solely as part of the Productincorporated into the OEM Products that and not on a standalonebasis. Customer
Manual No. DB11-000022-0008P5511LSI Logic CorporationNorth American HeadquartersMilpitas, CA408.433.8000
Trademark AcknowledgmentsLSI Logic, the LSI Logic logo, MORE, Mylex, and SANmapping are trademarks or registered trademarks of LSI Logic Corporation.
Commenti su questo manuale